P Series network-managed smart rack PDU with LCD and network interfaces

Rack Power Distribution · Smart Rack PDUs

P Series Smart Rack PDU with Monitoring & Remote Management

The P Series is a network-managed rack power distribution family with aggregate-monitored, per-outlet-monitored, switched, and per-outlet monitored-and-switched platforms. Supplier documentation lists configurable current, outlet, mounting and protocol options by platform.

4 platformsPA, PB, PC and PD

Monitoring + controlPlatform-dependent functions

4-32 outletsSupplier-listed platform options

Horizontal / verticalPlatform-dependent mounting

Product Overview

The P Series groups four smart rack PDU management architectures in one configurable family. PA provides aggregate electrical monitoring, PB adds per-outlet monitoring, PC combines aggregate monitoring with outlet switching, and PD combines per-outlet monitoring with outlet switching. Electrical ratings, outlet standards, outlet counts and mounting format are selection options rather than fixed PA/PB/PC/PD electrical SKUs.

Key Features

  • Four function platforms covering aggregate monitoring, per-outlet monitoring and remote outlet switching
  • Aggregate voltage, current, power, energy, power factor and frequency measurement across all four platforms
  • Per-outlet current, power and energy measurement on PB and PD
  • Per-outlet switching and sequencing on PC and PD
  • True-color LCD with Ethernet 10/100Base-T and RS-485 interfaces
  • Supplier-listed current options of 10A, 16A, 24A and 32A
  • Configurable Chinese-standard, IEC C13, US and UK outlet options

Available Platforms

PA, PB, PC and PD identify function platforms. Input current, outlet count and type, mounting format, input connection and cable length must be confirmed separately for quotation.

PlatformMonitoring / Control LevelEnvironmental InputsLoggingMountingSupplier-Listed Outlet Positions
PA – Aggregate MonitoredAggregate monitoring; no supplier-listed outlet-level monitoring or switching1 temperature / humidity channelAlarm and operation logsHorizontal4-32
PB – Per-Outlet MonitoredAggregate monitoring plus per-outlet current, power and energy measurement1 temperature / humidity channelAlarm and operation logsHorizontal4 / 8 / 12 / 16 / 20 / 24
PC – Aggregate Monitored + SwitchedAggregate monitoring with per-outlet switching and sequencingUp to 3 temperature / humidity channels plus 4 dry contactsAlarm and operation logsHorizontal or vertical4 / 8 / 12 / 16 / 20 / 24
PD – Per-Outlet Monitored + SwitchedPer-outlet monitoring with per-outlet switching and sequencing3 temperature / humidity channels plus 4 dry contactsAlarm and operation logsHorizontal or vertical4 / 8 / 12 / 16 / 20 / 24

Technical Specifications

Product TypeNetwork-managed smart rack PDU family
Supplier-Listed Input Voltage220V AC
Frequency50Hz
Supported Input Current Options10A, 16A, 24A or 32A; configurable and not fixed by platform
Supplier-Listed Family Working Power3000W rated; 6000W maximum; not mapped to individual current or outlet variants
Maximum Current per Output Socket10A
Verified Outlet OptionsChinese standard, IEC C13, US or UK
DisplayTrue-color LCD
InterfacesEthernet 10/100Base-T and RS-485
Aggregate MeasurementsVoltage, current, power, energy, power factor and frequency
Illustrated Rack Formats1U, 2U and 0U examples; availability depends on platform and outlet configuration

Smart Function & Protocol Comparison

Protocol and management functions are platform-specific. “Not listed” means the supplier matrix does not confirm that function for the platform.

Protocol / FunctionPAPBPCPD
IPv4 / IPv6YesYesYesYes
Modbus RTU / RS-485YesYesYesYes
Telnet / DHCP / HTTP / HTTPS / NTP / SMTPYesYesYesYes
SNMPNot listedYesYesYes
Modbus TCP / SSH / MQTTNot listedNot listedYesYes
Per-outlet measurementNoYesNoYes
Per-outlet switching / sequencingNoNoYesYes

Applications

The supporting image shows a rack inspection environment and does not depict a specific P Series configuration.

Rack PDU and server rack inspection in a data center environment

Data Center Racks

Rack-level power distribution and electrical monitoring for data center equipment.

Network Equipment Management

Remote monitoring and, on PC or PD, outlet-level control for network equipment.

Remote Power Cycling

Remote equipment power cycling with the switched PC and PD platforms.

Information to Confirm for Selection

  • Required platform: PA, PB, PC or PD
  • Input current option
  • Outlet count and outlet standard
  • Horizontal or vertical mounting requirement
  • Required communication protocols
  • Input connection and cable length
  • Quantity and rack application

FAQ

What is the difference between PA, PB, PC and PD?

PA provides aggregate monitoring, PB adds per-outlet monitoring, PC adds outlet switching to aggregate monitoring, and PD combines per-outlet monitoring with outlet switching.

Are PA, PB, PC and PD fixed electrical SKUs?

No. They identify function platforms. Current, outlet count and type, mounting, input connection and cable length are separate configuration choices.

Which outlet standards are verified for this family?

The supplier documentation lists Chinese-standard, IEC C13, US and UK outlet options.

Which platforms support remote outlet switching?

The supplier matrix lists per-outlet switching and sequencing for PC and PD.

What information is required for a quotation?

Provide the required platform, current option, outlet count and type, mounting format, communication requirements, input connection, cable length, quantity and application.

Request a Quote

Please provide the required PA/PB/PC/PD platform, input current, outlet count and type, mounting format, communication requirements, input connection, cable length, quantity and rack application.

Request Product Information & Pricing

Send model numbers, ratings, quantities and destination details. We will confirm availability before preparing a quotation.

Scroll to Top