Inquiry Now
VDT-20 DIN rail AC voltage transducer

Electrical Measurement & Monitoring · Voltage Transducers

VDT-20 DIN Rail AC Voltage Transducer

VDT-20 single-channel AC voltage transducers combine three standard input ranges with 4-20mA, 0-5V, 0-10V or RS485 output and 24V DC auxiliary supply.

0-100V to 0-500V ACThree standard input ranges

4 OutputsCurrent, voltage and RS485 options

0.5%Supplier-listed accuracy

35mm DIN RailMounting format

Product Overview

VDT-20 is a one-input, one-output AC voltage transducer for converting a selected AC voltage range into a standardized analog output or RS485 signal. Three documented input ranges and four output types form 12 standard configurations with a common 24V DC auxiliary supply.

Key Features

  • Single-channel AC voltage measurement
  • 0-100V, 0-300V and 0-500V AC inputs
  • 4-20mA DC, 0-5V, 0-10V and RS485 outputs
  • 24V DC auxiliary supply
  • Supplier-listed 0.5% accuracy
  • 35mm DIN-rail mounting
  • Compact 108 x 47 x 25.4mm maximum dimensions

Available Configurations

Select one AC input range and one output signal. All listed standard configurations use 24V DC auxiliary supply.

ConfigurationAC Input RangeOutput SignalAuxiliary Supply
VDT-20 0-100V / 4-20mA0-100V AC4-20mA DC24V DC
VDT-20 0-100V / 0-5V0-100V AC0-5V24V DC
VDT-20 0-100V / 0-10V0-100V AC0-10V24V DC
VDT-20 0-100V / RS4850-100V ACRS48524V DC
VDT-20 0-300V / 4-20mA0-300V AC4-20mA DC24V DC
VDT-20 0-300V / 0-5V0-300V AC0-5V24V DC
VDT-20 0-300V / 0-10V0-300V AC0-10V24V DC
VDT-20 0-300V / RS4850-300V ACRS48524V DC
VDT-20 0-500V / 4-20mA0-500V AC4-20mA DC24V DC
VDT-20 0-500V / 0-5V0-500V AC0-5V24V DC
VDT-20 0-500V / 0-10V0-500V AC0-10V24V DC
VDT-20 0-500V / RS4850-500V ACRS48524V DC

Technical Specifications

ModelVDT-20
Measurement TypeAC voltage
Channel ConfigurationOne input / one output
Standard Input Ranges0-100V AC / 0-300V AC / 0-500V AC
Output Options4-20mA DC / 0-5V / 0-10V / RS485
Auxiliary Supply24V DC
Accuracy0.5%
Mounting35mm DIN rail
Maximum Dimensions108 x 47 x 25.4mm

Frequency range, response time, isolation rating and output-load limits are not included because the available exact-family evidence does not confirm them.

Applications

The supporting image illustrates a general industrial electrical environment and does not show this product installed.

Illustrative industrial electrical control cabinet application environment

Electrical Control Cabinets

Conversion of an AC voltage signal for compatible PLC, controller or monitoring inputs.

Power Distribution Monitoring

DIN-rail voltage signal conversion for panel monitoring and data acquisition.

Industrial Automation Systems

Standardized analog or RS485 voltage measurement where the selected input/output pair matches the control system.

Information to Confirm for Selection

  • Required AC input range
  • Required output signal
  • 24V DC auxiliary supply availability
  • Analog receiving-input range or RS485 requirement
  • DIN-rail space and terminal access
  • Quantity and application

FAQ

Does VDT-20 measure AC or DC voltage?

The selected VDT-20 family is documented as an AC voltage transducer.

Are 0-5V and 0-10V input ranges?

No. They are output-signal options. The standard measured inputs are 0-100V, 0-300V and 0-500V AC.

What auxiliary supply is used?

The standard documented supply option used on this page is 24V DC.

Is an RS485 version available?

Yes. RS485 is one of four documented output options. Protocol details are not claimed in the available evidence.

Request a Quote

Provide the required AC input range, output signal, receiving-device interface, quantity and application.

Request Product Information & Pricing

Send model numbers, ratings, quantities and destination details. We will confirm availability before preparing a quotation.

Scroll to Top